Engineered Wood Flooring over Concrete and Radiant Heat

Concrete slabs and radiant heat are where engineered wood earns its place over solid hardwood. A few rules make the difference.

Concrete & radiant heat — HUDSON OAK guide cover

Why engineered wood suits concrete

Solid hardwood is usually nailed to a wood subfloor and moves noticeably with humidity, so it is rarely recommended directly over concrete. Engineered wood is built in layers that resist that movement, and it can be glued to the slab or installed as a floating floor. That is why it is the usual wood floor for slab-on-grade homes, condos and basements.

Test the concrete for moisture first

Concrete can release moisture for months after it is poured, and slabs on or below grade can draw moisture from the ground. Before any wood floor goes down, the slab should be tested and the results recorded. Two common tests:

  • ASTM F2170, in-situ relative humidity probes placed in holes drilled into the slab.
  • ASTM F1869, the calcium chloride test, which measures the moisture vapor emission rate at the surface.

Each flooring and adhesive manufacturer sets its own limits. For the HUDSON OAK Performance Collection they are in the installation instructions. New concrete generally needs at least 60 days to cure.

Glue-down or floating?

  • Glue-down: the boards are bonded to the slab with a wood flooring adhesive. It feels solid and quiet underfoot. Many urethane and silane-modified adhesives also act as a moisture barrier up to a stated level.
  • Floating: the floor rests on an underlayment over a polyethylene vapor retarder, with the boards joined to each other but not to the slab. It is quicker and suits slabs that cannot easily be prepared for adhesive.

Radiant floor heating

Engineered wood is one of the best wood floors for radiant heat, because its layered construction handles temperature changes better than solid boards. The key rules:

  • Use a system approved for wood floors, and for glue-down an adhesive approved for radiant heat.
  • Run a new system for several days before installation to dry the slab, then turn it down during installation.
  • Raise the temperature gradually afterwards, a few degrees a day.
  • Keep the floor surface no warmer than about 80°F (27°C). Higher temperatures dry the wood and can open gaps.

The HUDSON OAK Performance Collection can be installed glue-down or floating, and is compatible with radiant heating with a floor surface temperature up to 80°F (27°C).